A Discrete Semiconductor Manufacturer
You are in Bridge Rectifiers
Reverse Voltage Vr
Forward Current Io
Max Surge Current
Recovery Time
Package / Case
Mounting Style
Certified (AEC-Q101...etc)
Search Results ( 643 products found )
  • Item Description
  • Search Criteria
  • Item Description
  • RS1506MLS
  • Bridge Rectifiers - RS1506MLS rs1501mls-rs1507mls.pdf
  • Search Criteria
    • Part Number : RS1506MLS
    • Reverse Voltage Vr : 800 V
    • Forward Current Io : 15.0 A
    • Max Surge Current : 220 A
    • Forward Voltage Vf : 1.1 V
    • Reverse Current Ir : 0.2 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS15MLS
    • Mounting Style : Through-hole
    • Notes : RS15MLS,15A,800V,Bridge
    View Details
  • Item Description
  • RS1507MLS
  • Bridge Rectifiers - RS1507MLS rs1501mls-rs1507mls.pdf
  • Search Criteria
    • Part Number : RS1507MLS
    • Reverse Voltage Vr : 1000 V
    • Forward Current Io : 15.0 A
    • Max Surge Current : 220 A
    • Forward Voltage Vf : 1.1 V
    • Reverse Current Ir : 0.2 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS15MLS
    • Mounting Style : Through-hole
    • Notes : RS15MLS,15A,1000V,Bridge
    View Details
  • Item Description
  • RS2001MLS
  • Bridge Rectifiers - RS2001MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2001MLS
    • Reverse Voltage Vr : 50 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 150 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,50V,Bridge
    View Details
  • Item Description
  • RS2002MLS
  • Bridge Rectifiers - RS2002MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2002MLS
    • Reverse Voltage Vr : 100 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,100V,Bridge
    View Details
  • Item Description
  • RS2003MLS
  • Bridge Rectifiers - RS2003MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2003MLS
    • Reverse Voltage Vr : 200 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,200V,Bridge
    View Details
  • Item Description
  • RS2004MLS
  • Bridge Rectifiers - RS2004MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2004MLS
    • Reverse Voltage Vr : 400 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,400V,Bridge
    View Details
  • Item Description
  • RS2005MLS
  • Bridge Rectifiers - RS2005MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2005MLS
    • Reverse Voltage Vr : 600 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,600V,Bridge
    View Details
  • Item Description
  • RS2006MLS
  • Bridge Rectifiers - RS2006MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2006MLS
    • Reverse Voltage Vr : 800 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,800V,Bridge
    View Details
  • Item Description
  • RS2007MLS
  • Bridge Rectifiers - RS2007MLS rs2001mls-rs2007mls.pdf
  • Search Criteria
    • Part Number : RS2007MLS
    • Reverse Voltage Vr : 1000 V
    • Forward Current Io : 20.0 A
    • Max Surge Current : 240 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS20MLS
    • Mounting Style : Through-hole
    • Notes : RS20MLS,20A,1000V,Bridge
    View Details
  • Item Description
  • RS2501MLS
  • Bridge Rectifiers - RS2501MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2501MLS
    • Reverse Voltage Vr : 50 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,50V,Bridge
    View Details
  • Item Description
  • RS2502MLS
  • Bridge Rectifiers - RS2502MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2502MLS
    • Reverse Voltage Vr : 100 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,100V,Bridge
    View Details
  • Item Description
  • RS2503MLS
  • Bridge Rectifiers - RS2503MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2503MLS
    • Reverse Voltage Vr : 200 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,200V,Bridge
    View Details
  • Item Description
  • RS2504MLS
  • Bridge Rectifiers - RS2504MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2504MLS
    • Reverse Voltage Vr : 400 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,400V,Bridge
    View Details
  • Item Description
  • RS2505MLS
  • Bridge Rectifiers - RS2505MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2505MLS
    • Reverse Voltage Vr : 600 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,600V,Bridge
    View Details
  • Item Description
  • RS2506MLS
  • Bridge Rectifiers - RS2506MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2506MLS
    • Reverse Voltage Vr : 800 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,800V,Bridge
    View Details
  • Item Description
  • RS2507MLS
  • Bridge Rectifiers - RS2507MLS rs2501mls-rs2507mls.pdf
  • Search Criteria
    • Part Number : RS2507MLS
    • Reverse Voltage Vr : 1000 V
    • Forward Current Io : 25.0 A
    • Max Surge Current : 300 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : < 60 Hz
    • Package / Case : RS25MLS
    • Mounting Style : Through-hole
    • Notes : RS25MLS,25A,1000V,Bridge
    View Details
  • Item Description
  • ERBU404M
  • Bridge Rectifiers - ERBU404M erbu404m,erbu406m.pdf
  • Search Criteria
    • Part Number : ERBU404M
    • Reverse Voltage Vr : 200 V
    • Forward Current Io : 4.0 A
    • Max Surge Current : 75 A
    • Forward Voltage Vf : 1.0 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : 50 ns
    • Package / Case : RBU
    • Mounting Style : Through-hole
    • Notes : RBU,4A,200V,Bridge
    View Details
  • Item Description
  • ERBU406M
  • Bridge Rectifiers - ERBU406M erbu404m,erbu406m.pdf
  • Search Criteria
    • Part Number : ERBU406M
    • Reverse Voltage Vr : 400 V
    • Forward Current Io : 4.0 A
    • Max Surge Current : 75 A
    • Forward Voltage Vf : 1.25 V
    • Reverse Current Ir : 5 uA
    • Recovery Time : 50 ns
    • Package / Case : RBU
    • Mounting Style : Through-hole
    • Notes : RBU,4A,400V,Bridge
    View Details